Description

  • Certified to EN54-4/A2 by the LPCB & VdS (AFNOR pending).
  • A powerful switch mode/digital hybrid PSU that can be customised* to suit your exact requirements
  • Plastic cover on PSU PCB guards against touching live parts.
  • Includes a single-pole voltfree changeover relay that switches for any fault condition.
  • Multiple indicators – supply present, general fault, fault type & aux. equipment fault.
  • Two selectable battery charge currents.
  • Battery fault impedance limits can be optimised to suit load current (helps extend battery life)*.
  • Mains fail simulation mode.
  • Improved on-board temperature sensor with optional remote sensor.
  • Ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities.
  • Electronic functions comply with EN50131-6 grades 1-4 for security applications.
  • BF560-12/E Encased PCB version also available.

 

Technical Specifications

Application/operation

A boxed Mains to regulated DC switch-mode/digital hybrid power supply providing 2A @ 12V DC. It includes a single pole volt-free changeover relay that switches for any fault condition. User customi

Mains supply

230V 50/60Hz.

Mains rated current

300mA r.m.s.

Total output current limited to

2A (Max. output current).

Output

I max.a: 1.8A or 1.3A selectable. (1.8A not approved to EN54-4/A2). A load greater than I max.a will temporarily reduce batt. charging. I.max.b: 2A, charging turned off via CONN6. Output is also cu

Battery charge capacity

2Ah up to 12Ah (battery charged to 80% capacity in 24 hrs). Max. batt. size/type by cabinet size is 3.2Ah VRLA (with STU plate) or 7Ah (without STU plate). Output is customisable via a BF423 Confi

Max battery size and type

1 x 12V 3.2Ah VRLA (with STU plate fitted); 1 x 12V 7Ah VRLA (without STU plate fitted).

Indicators

3 external – Supply Present (Green); General Fault (Amber); Auxiliary Fault (Amber) and 2 internal – Hazardous Voltages Present (Red) and PSU Status (Amber).

Connections

Mains Input (CONN1); Supply Output (CONN5); Battery Input (CONN5); Fault Relay (CONN4); BF423 Configurator Connector* (PL2); Remote Thermistor Connector (PL3); Batt. Charger Inhibit & Input/Output

Expansion connections

A remote thermistor can be connected via PL3 terminals.

Product dimensions (mm)

380mm W x 235mm H x 96mm D.

Construction & finish

PVC lid and base; RAL7035 textured.

IP Rating

IP30 (to EN 60529). Designed for indoor use only.

Weight

1.55kg (without batteries).

Operating conditions/temperature

-5ºC to +40ºC. Max relative humidity: 95%.

Notes

*Parameters configurable via a BF423 configurator are: Float voltage temp. compensation; Batt. charge rate (mA); Batt. impedance; Configurable Input/Output settings. Note: Changing the PSU's parame

 

Download Data Sheets

Click the PDF to download each individual data sheet.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
C-Tec

PSU 5 Series 12V 2A boxed Switch Mode

£94.35 excl. VAT

 

Technical Specifications

Application/operation

A boxed Mains to regulated DC switch-mode/digital hybrid power supply providing 2A @ 12V DC. It includes a single pole volt-free changeover relay that switches for any fault condition. User customi

Mains supply

230V 50/60Hz.

Mains rated current

300mA r.m.s.

Total output current limited to

2A (Max. output current).

Output

I max.a: 1.8A or 1.3A selectable. (1.8A not approved to EN54-4/A2). A load greater than I max.a will temporarily reduce batt. charging. I.max.b: 2A, charging turned off via CONN6. Output is also cu

Battery charge capacity

2Ah up to 12Ah (battery charged to 80% capacity in 24 hrs). Max. batt. size/type by cabinet size is 3.2Ah VRLA (with STU plate) or 7Ah (without STU plate). Output is customisable via a BF423 Confi

Max battery size and type

1 x 12V 3.2Ah VRLA (with STU plate fitted); 1 x 12V 7Ah VRLA (without STU plate fitted).

Indicators

3 external – Supply Present (Green); General Fault (Amber); Auxiliary Fault (Amber) and 2 internal – Hazardous Voltages Present (Red) and PSU Status (Amber).

Connections

Mains Input (CONN1); Supply Output (CONN5); Battery Input (CONN5); Fault Relay (CONN4); BF423 Configurator Connector* (PL2); Remote Thermistor Connector (PL3); Batt. Charger Inhibit & Input/Output

Expansion connections

A remote thermistor can be connected via PL3 terminals.

Product dimensions (mm)

380mm W x 235mm H x 96mm D.

Construction & finish

PVC lid and base; RAL7035 textured.

IP Rating

IP30 (to EN 60529). Designed for indoor use only.

Weight

1.55kg (without batteries).

Operating conditions/temperature

-5ºC to +40ºC. Max relative humidity: 95%.

Notes

*Parameters configurable via a BF423 configurator are: Float voltage temp. compensation; Batt. charge rate (mA); Batt. impedance; Configurable Input/Output settings. Note: Changing the PSU's parame

 