8A Single Zone Smoke Vent Control Panel c/w 2 Natvent Groups
Product Code:
RZN4408-K
£536.92
excl. VAT
Unit price
excl. VAT /
Unavailable
8A Single Zone Smoke Vent Control Panel c/w 2 Natvent Groups is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Description
Description
- Compact SHEV control panel - AdComNet ready
- Tested and certified according to ISO 21927‑9, VdS 2581, VdS 2593, VdS 2344 and DIN EN 12101‑10, fulfils the building authority requirements in accordance with DIN 18232-9
- Up to 8 A total drive current
- Stabilised output voltage
- Switchable SHEV safety functions: Fault equal to alarm, SHEV retriggering function and smoke detector remote reset
- Option to combine SHEV / building alarm function
- Integrated comfort functions for daily ventilation
- Optional connection to rain detectors or wind / rain sensors without an additional module
- Connection of up to 8 SHEV operation panels and 14 fire detectors per line (Only detectors permitted by D+H may be used)
- Min. 72 hr battery backup supply
Performance features:
- SHEV controller - AdComNet ready.
- The SHEV control panel is tested and certified according to ISO 21927-9, VdS 2581, VdS 2593, VdS 2344 and DIN EN 12101-10 and also fulfils the building authority requirements in accordance with DIN 18232-9.
- Stabilised output voltage.
- A maximum of 8 SHEV operation panels and 14 fire detectors can be connected per line (only detectors approved by D+H may be used).
- Min. 72 hr battery backup supply.
- Temperature-controlled battery charge.
- Batterie charge and status check.
- Switchable SHEV functions: Fault equal to alarm.
- SHEV retriggering function and smoke detector remote reset.
- Codable SHEV- and ventilation functions.
- Combination of a SHEV- / building alarm function possible.
- Comfort ventilation functions.
- Line monitoring for short circuit and interruption.
- Slot for additional module.
- Connection options for optical and acoustical alarm devices.
- Usable for daily ventilation.
- Ventilation time and opening width adjustable.
- Wind/rain sensor connectable without additional module
Download Data Sheets
Click the PDF to download each individual data sheet.
- RZN_4408-K.pdf PDF
- Installation Instructions
Datasheet
{"id":15058329829762,"title":"8A Single Zone Smoke Vent Control Panel c\/w 2 Natvent Groups","handle":"8a-single-zone-smoke-vent-control-panel-c-w-2-natvent-groups","description":"\u003cul\u003e\n\u003cli\u003eCompact SHEV control panel - AdComNet ready\u003c\/li\u003e\n\u003cli\u003eTested and certified according to ISO 21927‑9, VdS 2581, VdS 2593, VdS 2344 and DIN EN 12101‑10, fulfils the building authority requirements in accordance with DIN 18232-9\u003c\/li\u003e\n\u003cli\u003eUp to 8 A total drive current\u003c\/li\u003e\n\u003cli\u003eStabilised output voltage\u003c\/li\u003e\n\u003cli\u003eSwitchable SHEV safety functions: Fault equal to alarm, SHEV retriggering function and smoke detector remote reset\u003c\/li\u003e\n\u003cli\u003eOption to combine SHEV \/ building alarm function\u003c\/li\u003e\n\u003cli\u003eIntegrated comfort functions for daily ventilation\u003c\/li\u003e\n\u003cli\u003eOptional connection to rain detectors or wind \/ rain sensors without an additional module\u003c\/li\u003e\n\u003cli\u003eConnection of up to 8 SHEV operation panels and 14 fire detectors per line (Only detectors permitted by D+H may be used)\u003c\/li\u003e\n\u003cli\u003eMin. 72 hr battery backup supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e Performance features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSHEV controller - AdComNet ready.\u003c\/li\u003e\n\u003cli\u003eThe SHEV control panel is tested and certified according to ISO 21927-9, VdS 2581, VdS 2593, VdS 2344 and DIN EN 12101-10 and also fulfils the building authority requirements in accordance with DIN 18232-9.\u003c\/li\u003e\n\u003cli\u003eStabilised output voltage.\u003c\/li\u003e\n\u003cli\u003eA maximum of 8 SHEV operation panels and 14 fire detectors can be connected per line (only detectors approved by D+H may be used).\u003c\/li\u003e\n\u003cli\u003eMin. 72 hr battery backup supply.\u003c\/li\u003e\n\u003cli\u003eTemperature-controlled battery charge.\u003c\/li\u003e\n\u003cli\u003eBatterie charge and status check.\u003c\/li\u003e\n\u003cli\u003eSwitchable SHEV functions: Fault equal to alarm.\u003c\/li\u003e\n\u003cli\u003eSHEV retriggering function and smoke detector remote reset.\u003c\/li\u003e\n\u003cli\u003eCodable SHEV- and ventilation functions.\u003c\/li\u003e\n\u003cli\u003eCombination of a SHEV- \/ building alarm function possible.\u003c\/li\u003e\n\u003cli\u003eComfort ventilation functions.\u003c\/li\u003e\n\u003cli\u003eLine monitoring for short circuit and interruption.\u003c\/li\u003e\n\u003cli\u003eSlot for additional module.\u003c\/li\u003e\n\u003cli\u003eConnection options for optical and acoustical alarm devices.\u003c\/li\u003e\n\u003cli\u003eUsable for daily ventilation.\u003c\/li\u003e\n\u003cli\u003eVentilation time and opening width adjustable.\u003c\/li\u003e\n\u003cli\u003eWind\/rain sensor connectable without additional module\u003c\/li\u003e\n\u003c\/ul\u003e","published_at":"2025-08-11T11:00:35+01:00","created_at":"2025-08-07T11:20:20+01:00","vendor":"D+H","type":"Smoke Ventilation Controls","tags":["Control panel","Control Panels","D+H","Smoke Ventilation Controls"],"price":53692,"price_min":53692,"price_max":53692,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":55534315372930,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"RZN4408-K","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"8A Single Zone Smoke Vent Control Panel c\/w 2 Natvent Groups","public_title":null,"options":["Default Title"],"price":53692,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.inbuilduk.com\/cdn\/shop\/files\/PIC_PRO_EIN_ZP-RZN-4408-K_ALL_2x_266e97eb-7155-4ebf-9a38-5e1d119bfb72.webp?v=1754647577"],"featured_image":"\/\/www.inbuilduk.com\/cdn\/shop\/files\/PIC_PRO_EIN_ZP-RZN-4408-K_ALL_2x_266e97eb-7155-4ebf-9a38-5e1d119bfb72.webp?v=1754647577","options":["Title"],"media":[{"alt":null,"id":65247967084930,"position":1,"preview_image":{"aspect_ratio":1.995,"height":770,"width":1536,"src":"\/\/www.inbuilduk.com\/cdn\/shop\/files\/PIC_PRO_EIN_ZP-RZN-4408-K_ALL_2x_266e97eb-7155-4ebf-9a38-5e1d119bfb72.webp?v=1754647577"},"aspect_ratio":1.995,"height":770,"media_type":"image","src":"\/\/www.inbuilduk.com\/cdn\/shop\/files\/PIC_PRO_EIN_ZP-RZN-4408-K_ALL_2x_266e97eb-7155-4ebf-9a38-5e1d119bfb72.webp?v=1754647577","width":1536}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli\u003eCompact SHEV control panel - AdComNet ready\u003c\/li\u003e\n\u003cli\u003eTested and certified according to ISO 21927‑9, VdS 2581, VdS 2593, VdS 2344 and DIN EN 12101‑10, fulfils the building authority requirements in accordance with DIN 18232-9\u003c\/li\u003e\n\u003cli\u003eUp to 8 A total drive current\u003c\/li\u003e\n\u003cli\u003eStabilised output voltage\u003c\/li\u003e\n\u003cli\u003eSwitchable SHEV safety functions: Fault equal to alarm, SHEV retriggering function and smoke detector remote reset\u003c\/li\u003e\n\u003cli\u003eOption to combine SHEV \/ building alarm function\u003c\/li\u003e\n\u003cli\u003eIntegrated comfort functions for daily ventilation\u003c\/li\u003e\n\u003cli\u003eOptional connection to rain detectors or wind \/ rain sensors without an additional module\u003c\/li\u003e\n\u003cli\u003eConnection of up to 8 SHEV operation panels and 14 fire detectors per line (Only detectors permitted by D+H may be used)\u003c\/li\u003e\n\u003cli\u003eMin. 72 hr battery backup supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e Performance features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSHEV controller - AdComNet ready.\u003c\/li\u003e\n\u003cli\u003eThe SHEV control panel is tested and certified according to ISO 21927-9, VdS 2581, VdS 2593, VdS 2344 and DIN EN 12101-10 and also fulfils the building authority requirements in accordance with DIN 18232-9.\u003c\/li\u003e\n\u003cli\u003eStabilised output voltage.\u003c\/li\u003e\n\u003cli\u003eA maximum of 8 SHEV operation panels and 14 fire detectors can be connected per line (only detectors approved by D+H may be used).\u003c\/li\u003e\n\u003cli\u003eMin. 72 hr battery backup supply.\u003c\/li\u003e\n\u003cli\u003eTemperature-controlled battery charge.\u003c\/li\u003e\n\u003cli\u003eBatterie charge and status check.\u003c\/li\u003e\n\u003cli\u003eSwitchable SHEV functions: Fault equal to alarm.\u003c\/li\u003e\n\u003cli\u003eSHEV retriggering function and smoke detector remote reset.\u003c\/li\u003e\n\u003cli\u003eCodable SHEV- and ventilation functions.\u003c\/li\u003e\n\u003cli\u003eCombination of a SHEV- \/ building alarm function possible.\u003c\/li\u003e\n\u003cli\u003eComfort ventilation functions.\u003c\/li\u003e\n\u003cli\u003eLine monitoring for short circuit and interruption.\u003c\/li\u003e\n\u003cli\u003eSlot for additional module.\u003c\/li\u003e\n\u003cli\u003eConnection options for optical and acoustical alarm devices.\u003c\/li\u003e\n\u003cli\u003eUsable for daily ventilation.\u003c\/li\u003e\n\u003cli\u003eVentilation time and opening width adjustable.\u003c\/li\u003e\n\u003cli\u003eWind\/rain sensor connectable without additional module\u003c\/li\u003e\n\u003c\/ul\u003e"}