Zeta SP-252/M Simplicity Plus 252 Analogue Addressable Fire Alarm Panel - 2 Loop, 252 Devices (Metal Enclosure)

The Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.

As its name suggests, it has been designed with ease of use in mind, using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad (optional).

The Simplicity Plus has user definable zones, option for zonal or common alarm operation, options for I/O operation, alarm verification and user selectable languages.

It can be connected to an RS232 desktop printer for real time event log printing (Epson LQ300+ recommended) and it can also drive a serial repeater model SP/REP (Part No. 37-179).

Alarm Verification

To help prevent false alarm causing a full evacuation, any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detector’s LEDs and sound/flasher base (if connected) will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.

Zonal Addressing

All devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.

Key Features

  • 2 Loop, 252 Devices
  • Certified to EN54 parts 2 & 4
  • User definable zones
  • Option for zonal or common alarm operation
  • Options for I/O operation
  • Alarm verification (help prevent false alarms)
  • User selectable languages
  • Set of changeover relay contacts for fault condition
  • Set of changeover relay contacts for fire condition
  • 2,048 event log (fire & fault)
  • Zone or device disablement
  • One-man test mode
  • Plug & play, no need for any special tools or laptop for commissioning
  • Fully integrated keypad
  • All associated devices are loop powered
  • Supply Voltage: 230V AC +/- 10%
  • System Voltage: 24V DC (Nominal)
  • Enclosure Size: 375mm x 335mm x 125mm

Download Data Sheets

Click the PDF to download each individual data sheet.

{"id":15034257375618,"title":"Zeta Simplicity Plus 252 (2 Loop, 252 Devices) Addressable Panel (Metal Enclosure)","handle":"simplicity-plus-252-2-loop-252-devices-addressable-panel-metal-enclosure","description":"\u003cdiv class=\"tab-pane active\" id=\"tab-description\"\u003e\n\u003cp\u003e\u003cstrong\u003eZeta SP-252\/M Simplicity Plus 252 Analogue Addressable Fire Alarm Panel - 2 Loop, 252 Devices (Metal Enclosure)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.\u003c\/p\u003e\n\u003cp\u003eAs its name suggests, it has been designed with ease of use in mind, using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad (optional).\u003c\/p\u003e\n\u003cp\u003eThe Simplicity Plus has user definable zones, option for zonal or common alarm operation, options for I\/O operation, alarm verification and user selectable languages.\u003c\/p\u003e\n\u003cp\u003eIt can be connected to an RS232 desktop printer for real time event log printing (Epson LQ300+ recommended) and it can also drive a serial repeater model SP\/REP (Part No. 37-179).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Verification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo help prevent false alarm causing a full evacuation, any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detector’s LEDs and sound\/flasher base (if connected) will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eZonal Addressing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Loop, 252 Devices\u003c\/li\u003e\n\u003cli\u003eCertified to EN54 parts 2 \u0026amp; 4\u003c\/li\u003e\n\u003cli\u003eUser definable zones\u003c\/li\u003e\n\u003cli\u003eOption for zonal or common alarm operation\u003c\/li\u003e\n\u003cli\u003eOptions for I\/O operation\u003c\/li\u003e\n\u003cli\u003eAlarm verification (help prevent false alarms)\u003c\/li\u003e\n\u003cli\u003eUser selectable languages\u003c\/li\u003e\n\u003cli\u003eSet of changeover relay contacts for fault condition\u003c\/li\u003e\n\u003cli\u003eSet of changeover relay contacts for fire condition\u003c\/li\u003e\n\u003cli\u003e2,048 event log (fire \u0026amp; fault)\u003c\/li\u003e\n\u003cli\u003eZone or device disablement\u003c\/li\u003e\n\u003cli\u003eOne-man test mode\u003c\/li\u003e\n\u003cli\u003ePlug \u0026amp; play, no need for any special tools or laptop for commissioning\u003c\/li\u003e\n\u003cli\u003eFully integrated keypad\u003c\/li\u003e\n\u003cli\u003eAll associated devices are loop powered\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230V AC +\/- 10%\u003c\/li\u003e\n\u003cli\u003eSystem Voltage: 24V DC (Nominal)\u003c\/li\u003e\n\u003cli\u003eEnclosure Size: 375mm x 335mm x 125mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","published_at":"2025-08-04T14:13:32+01:00","created_at":"2025-07-16T10:31:24+01:00","vendor":"Zeta","type":"Addressable Fire Alarm Panels","tags":["Addressable","Addressable enclosures","Addressable Panel","Fire Detection","Zeta"],"price":64504,"price_min":64504,"price_max":64504,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":55422057447810,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HUVO-SP-252\/M","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Zeta Simplicity Plus 252 (2 Loop, 252 Devices) Addressable Panel (Metal Enclosure)","public_title":null,"options":["Default Title"],"price":64504,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.inbuilduk.com\/cdn\/shop\/files\/SP-REP.png?v=1753274125"],"featured_image":"\/\/www.inbuilduk.com\/cdn\/shop\/files\/SP-REP.png?v=1753274125","options":["Title"],"media":[{"alt":null,"id":65132653019522,"position":1,"preview_image":{"aspect_ratio":1.0,"height":2000,"width":2000,"src":"\/\/www.inbuilduk.com\/cdn\/shop\/files\/SP-REP.png?v=1753274125"},"aspect_ratio":1.0,"height":2000,"media_type":"image","src":"\/\/www.inbuilduk.com\/cdn\/shop\/files\/SP-REP.png?v=1753274125","width":2000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv class=\"tab-pane active\" id=\"tab-description\"\u003e\n\u003cp\u003e\u003cstrong\u003eZeta SP-252\/M Simplicity Plus 252 Analogue Addressable Fire Alarm Panel - 2 Loop, 252 Devices (Metal Enclosure)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.\u003c\/p\u003e\n\u003cp\u003eAs its name suggests, it has been designed with ease of use in mind, using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad (optional).\u003c\/p\u003e\n\u003cp\u003eThe Simplicity Plus has user definable zones, option for zonal or common alarm operation, options for I\/O operation, alarm verification and user selectable languages.\u003c\/p\u003e\n\u003cp\u003eIt can be connected to an RS232 desktop printer for real time event log printing (Epson LQ300+ recommended) and it can also drive a serial repeater model SP\/REP (Part No. 37-179).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Verification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo help prevent false alarm causing a full evacuation, any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detector’s LEDs and sound\/flasher base (if connected) will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eZonal Addressing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Loop, 252 Devices\u003c\/li\u003e\n\u003cli\u003eCertified to EN54 parts 2 \u0026amp; 4\u003c\/li\u003e\n\u003cli\u003eUser definable zones\u003c\/li\u003e\n\u003cli\u003eOption for zonal or common alarm operation\u003c\/li\u003e\n\u003cli\u003eOptions for I\/O operation\u003c\/li\u003e\n\u003cli\u003eAlarm verification (help prevent false alarms)\u003c\/li\u003e\n\u003cli\u003eUser selectable languages\u003c\/li\u003e\n\u003cli\u003eSet of changeover relay contacts for fault condition\u003c\/li\u003e\n\u003cli\u003eSet of changeover relay contacts for fire condition\u003c\/li\u003e\n\u003cli\u003e2,048 event log (fire \u0026amp; fault)\u003c\/li\u003e\n\u003cli\u003eZone or device disablement\u003c\/li\u003e\n\u003cli\u003eOne-man test mode\u003c\/li\u003e\n\u003cli\u003ePlug \u0026amp; play, no need for any special tools or laptop for commissioning\u003c\/li\u003e\n\u003cli\u003eFully integrated keypad\u003c\/li\u003e\n\u003cli\u003eAll associated devices are loop powered\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230V AC +\/- 10%\u003c\/li\u003e\n\u003cli\u003eSystem Voltage: 24V DC (Nominal)\u003c\/li\u003e\n\u003cli\u003eEnclosure Size: 375mm x 335mm x 125mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e"}
Zeta

Zeta Simplicity Plus 252 (2 Loop, 252 Devices) Addressable Panel (Metal Enclosure)

£645.04 excl. VAT

Zeta SP-252/M Simplicity Plus 252 Analogue Addressable Fire Alarm Panel - 2 Loop, 252 Devices (Metal Enclosure)

The Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.

As its name suggests, it has been designed with ease of use in mind, using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad (optional).

The Simplicity Plus has user definable zones, option for zonal or common alarm operation, options for I/O operation, alarm verification and user selectable languages.

It can be connected to an RS232 desktop printer for real time event log printing (Epson LQ300+ recommended) and it can also drive a serial repeater model SP/REP (Part No. 37-179).

Alarm Verification

To help prevent false alarm causing a full evacuation, any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detector’s LEDs and sound/flasher base (if connected) will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.

Zonal Addressing

All devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.

Key Features

  • 2 Loop, 252 Devices
  • Certified to EN54 parts 2 & 4
  • User definable zones
  • Option for zonal or common alarm operation
  • Options for I/O operation
  • Alarm verification (help prevent false alarms)
  • User selectable languages
  • Set of changeover relay contacts for fault condition
  • Set of changeover relay contacts for fire condition
  • 2,048 event log (fire & fault)
  • Zone or device disablement
  • One-man test mode
  • Plug & play, no need for any special tools or laptop for commissioning
  • Fully integrated keypad
  • All associated devices are loop powered
  • Supply Voltage: 230V AC +/- 10%
  • System Voltage: 24V DC (Nominal)
  • Enclosure Size: 375mm x 335mm x 125mm
View product
{"id":15034257375618,"title":"Zeta Simplicity Plus 252 (2 Loop, 252 Devices) Addressable Panel (Metal Enclosure)","handle":"simplicity-plus-252-2-loop-252-devices-addressable-panel-metal-enclosure","description":"\u003cdiv class=\"tab-pane active\" id=\"tab-description\"\u003e\n\u003cp\u003e\u003cstrong\u003eZeta SP-252\/M Simplicity Plus 252 Analogue Addressable Fire Alarm Panel - 2 Loop, 252 Devices (Metal Enclosure)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.\u003c\/p\u003e\n\u003cp\u003eAs its name suggests, it has been designed with ease of use in mind, using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad (optional).\u003c\/p\u003e\n\u003cp\u003eThe Simplicity Plus has user definable zones, option for zonal or common alarm operation, options for I\/O operation, alarm verification and user selectable languages.\u003c\/p\u003e\n\u003cp\u003eIt can be connected to an RS232 desktop printer for real time event log printing (Epson LQ300+ recommended) and it can also drive a serial repeater model SP\/REP (Part No. 37-179).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Verification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo help prevent false alarm causing a full evacuation, any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detector’s LEDs and sound\/flasher base (if connected) will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eZonal Addressing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Loop, 252 Devices\u003c\/li\u003e\n\u003cli\u003eCertified to EN54 parts 2 \u0026amp; 4\u003c\/li\u003e\n\u003cli\u003eUser definable zones\u003c\/li\u003e\n\u003cli\u003eOption for zonal or common alarm operation\u003c\/li\u003e\n\u003cli\u003eOptions for I\/O operation\u003c\/li\u003e\n\u003cli\u003eAlarm verification (help prevent false alarms)\u003c\/li\u003e\n\u003cli\u003eUser selectable languages\u003c\/li\u003e\n\u003cli\u003eSet of changeover relay contacts for fault condition\u003c\/li\u003e\n\u003cli\u003eSet of changeover relay contacts for fire condition\u003c\/li\u003e\n\u003cli\u003e2,048 event log (fire \u0026amp; fault)\u003c\/li\u003e\n\u003cli\u003eZone or device disablement\u003c\/li\u003e\n\u003cli\u003eOne-man test mode\u003c\/li\u003e\n\u003cli\u003ePlug \u0026amp; play, no need for any special tools or laptop for commissioning\u003c\/li\u003e\n\u003cli\u003eFully integrated keypad\u003c\/li\u003e\n\u003cli\u003eAll associated devices are loop powered\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230V AC +\/- 10%\u003c\/li\u003e\n\u003cli\u003eSystem Voltage: 24V DC (Nominal)\u003c\/li\u003e\n\u003cli\u003eEnclosure Size: 375mm x 335mm x 125mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","published_at":"2025-08-04T14:13:32+01:00","created_at":"2025-07-16T10:31:24+01:00","vendor":"Zeta","type":"Addressable Fire Alarm Panels","tags":["Addressable","Addressable enclosures","Addressable Panel","Fire Detection","Zeta"],"price":64504,"price_min":64504,"price_max":64504,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":55422057447810,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HUVO-SP-252\/M","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Zeta Simplicity Plus 252 (2 Loop, 252 Devices) Addressable Panel (Metal Enclosure)","public_title":null,"options":["Default Title"],"price":64504,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.inbuilduk.com\/cdn\/shop\/files\/SP-REP.png?v=1753274125"],"featured_image":"\/\/www.inbuilduk.com\/cdn\/shop\/files\/SP-REP.png?v=1753274125","options":["Title"],"media":[{"alt":null,"id":65132653019522,"position":1,"preview_image":{"aspect_ratio":1.0,"height":2000,"width":2000,"src":"\/\/www.inbuilduk.com\/cdn\/shop\/files\/SP-REP.png?v=1753274125"},"aspect_ratio":1.0,"height":2000,"media_type":"image","src":"\/\/www.inbuilduk.com\/cdn\/shop\/files\/SP-REP.png?v=1753274125","width":2000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv class=\"tab-pane active\" id=\"tab-description\"\u003e\n\u003cp\u003e\u003cstrong\u003eZeta SP-252\/M Simplicity Plus 252 Analogue Addressable Fire Alarm Panel - 2 Loop, 252 Devices (Metal Enclosure)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.\u003c\/p\u003e\n\u003cp\u003eAs its name suggests, it has been designed with ease of use in mind, using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad (optional).\u003c\/p\u003e\n\u003cp\u003eThe Simplicity Plus has user definable zones, option for zonal or common alarm operation, options for I\/O operation, alarm verification and user selectable languages.\u003c\/p\u003e\n\u003cp\u003eIt can be connected to an RS232 desktop printer for real time event log printing (Epson LQ300+ recommended) and it can also drive a serial repeater model SP\/REP (Part No. 37-179).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Verification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo help prevent false alarm causing a full evacuation, any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detector’s LEDs and sound\/flasher base (if connected) will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eZonal Addressing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Loop, 252 Devices\u003c\/li\u003e\n\u003cli\u003eCertified to EN54 parts 2 \u0026amp; 4\u003c\/li\u003e\n\u003cli\u003eUser definable zones\u003c\/li\u003e\n\u003cli\u003eOption for zonal or common alarm operation\u003c\/li\u003e\n\u003cli\u003eOptions for I\/O operation\u003c\/li\u003e\n\u003cli\u003eAlarm verification (help prevent false alarms)\u003c\/li\u003e\n\u003cli\u003eUser selectable languages\u003c\/li\u003e\n\u003cli\u003eSet of changeover relay contacts for fault condition\u003c\/li\u003e\n\u003cli\u003eSet of changeover relay contacts for fire condition\u003c\/li\u003e\n\u003cli\u003e2,048 event log (fire \u0026amp; fault)\u003c\/li\u003e\n\u003cli\u003eZone or device disablement\u003c\/li\u003e\n\u003cli\u003eOne-man test mode\u003c\/li\u003e\n\u003cli\u003ePlug \u0026amp; play, no need for any special tools or laptop for commissioning\u003c\/li\u003e\n\u003cli\u003eFully integrated keypad\u003c\/li\u003e\n\u003cli\u003eAll associated devices are loop powered\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230V AC +\/- 10%\u003c\/li\u003e\n\u003cli\u003eSystem Voltage: 24V DC (Nominal)\u003c\/li\u003e\n\u003cli\u003eEnclosure Size: 375mm x 335mm x 125mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e"}